Cpex-1 can accurately measure data in a wide range of fields, from measuring basal metabolism at rest to creating exercise prescriptions for cardiac rehabilitation, evaluating the effectiveness of treatment for cardiac and respiratory diseases, and measuring exercise capacity in athletes.
| Dimensions |
Main unit: 20(W)×30(D)×18.5(H)cm Dedicated cart: 64.4(W)×66(D)×91.2(H)cm |
| Weight | 28kg |
| Power | AC100V,60/60Hz |
| Power consumption | 30VA |
| Operating temperature | 10-40℃ |
| level of humidity | 30-75% (no condensation) |
| configuration |
・Cpex-1 main unit ・Syringe for ventilometer calibration ・Exhalation masks (2 pcs) ・Ventilometer ・Sampling tube ・Isolation transformer ・Data processing PC (OS: Windows) ・Monitor ・Dedicated cart ・Calibration gas ・Isolation transformer |
01 |
The "Sample Gas Transfer Time Automatic Assurance System" enables highly accurate measurements. Equipped with high-response O₂ and CO₂ sensors and a respiratory flow meter, it continuously monitors ventilation flow rate, O₂ concentration, and CO₂ concentration on a breath-by-breath basis (with real-time display capability). This ensures reliable measurements without errors, regardless of exercise intensity.


02 |
Cpex-1’s one-click calibration and automated analytics allow users of all skill levels to easily obtain accurate, reproducible data. The previously cumbersome calibration process is now done with just a single click. Scale adjustments and parameter changes can be made in real time, while measuring. The automated analytics and triangular visual indicators Cpex-1 provides make it easy even for less-experienced users to accurately determine the anaerobic threshold (AT point), a key indicator for exercise prescriptions.
03 |
The reference values used for evaluation in the final report are authorized for commercial use by the original authors and provide the only standard in Japan for assessing the exercise capacity of test subjects.
Reference Source: J Cardiology 2013:61:71-78
The individual values from the comprehensive report are compared and evaluated against reference values for healthy individuals, categorized by age and gender.
Reports Include:
・Dr. Wassermann's Standard 9 Reports
・Cpex-1 Original 3 Reports
・Exercise Guidance Report
・Nutrition Management Report
This system has been adopted as the practical training device for cardiopulmonary exercise testing at exercise prescription seminars hosted by JHC (Japan Heart Club).
CONTACT

Inter Reha Co., Ltd.
1-37-15 Kaminakazato, Kita-ku, Tokyo 114-0016 Japan
TEL:+81-3-5974-0231
FAX:TEL:+81-3-5974-0233
International Sales Partners
KOREA
Apsun Corporation
3 Macheon-ro 27-gil, Songpa-gu, Seoul, Republic of Korea 05731
TEL:+82-2-443-4456
FAX:+82-2-401-5271
info@apsuncorp.com
https://www.apsuncorp.com
TAIWAN (R.O.C.)
Habitz Medtech Co., LTD
1F, No. 147-1, Sec. 2, Jianguo N. Rd., Zhongshan Dist., Taipei City, 104476
TEL:+886-2-8789-998
FAX:+886-2-8789-9685
ct@habitz.com.tw
https://www.habitz-medtech.com
THAILAND
Ufam Clinique Co., Ltd.
1296/69-71 Krungthep-Nonthaburi Road Bangsue, Bangkok, 10800
TEL:+66-2-911-2801-2
FAX+66-2-911-4786
https://ufamclinique.com
Copyright © Inter Reha Co.,Ltd.